Factory Reset
- Unlock the battery cover and slide it upwards to remove it.
- Press upward on the tamper switch located in-between the batteries, keeping it engaged while you remove both batteries.
- Wait at least 4 seconds, but do not release the tamper switch.
- Keep the tamper switch engaged while you reinsert both batteries.
- Release the tamper switch. The device is now reset to factory default settings.
Join the Zigbee Network
- Unlock the battery cover and slide it upwards to remove it.
- From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
- Remove both batteries for at least 10 seconds.
- Reinsert both batteries. The LED on the front of the sensor will be solid for 2 seconds
- The LED will begin to flash On > Off > On > Off > On > Off (for 5 seconds) and will continue to flash in this cycle for up to 3 minutes
- If the motion sensor does not pair with the hub in less than 3 minutes, perform a factory reset and repeat the above steps to join the Zigbee network.
Leaving the Zigbee Network
- From the device's details page, select Remove Device, then Remove.
Device
Product Number
Device Type
Protocol
PIR Motion Detector
ISW-ZPR1-WP13
Motion Detector
Zigbee
Device
Product Number
Device Type
Protocol
PIR Motion Detector
ISW-ZDL1-WP11G
Motion Detector
Zigbee
Factory Reset
- Unlock the battery cover and slide it upwards to remove it.
- Press upward on the tamper switch located in-between the batteries, keeping it engaged while you remove both batteries.
- Wait at least 4 seconds, but do not release the tamper switch.
- Keep the tamper switch engaged while you reinsert both batteries.
- Release the tamper switch. The device is now reset to factory default settings.
Join the Zigbee Network
- Unlock the battery cover and slide it upwards to remove it.
- From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
- Remove both batteries for at least 10 seconds.
- Reinsert both batteries. The LED on the front of the sensor will be solid for 2 seconds
- The LED will begin to flash On > Off > On > Off > On > Off (for 5 seconds) and will continue to flash in this cycle for up to 3 minutes
- If the motion sensor does not pair with the hub in less than 3 minutes, perform a factory reset and repeat the above steps to join the Zigbee network.
Leaving the Zigbee Network
- From the device's details page, select Remove Device, then Remove.