Factory Reset

  1. Unplug the PD-100 and anything that is plugged into it.
  2. Press and hold the button on the front of the PD-100
  3. Plug the PD-100 in while still pressing the button
  4. After 3 seconds, release the button. If the button flashes, the PD-100 has been successfully reset. If not, repeat the steps to factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the button on the front of the PD-100

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the button on the front of the PD-100

Device

Product Number

Device Type

Protocol

Plug in Z-Wave Plus Dimmer Switch

PD-100

Dimmer