How to add and reset Everspring products on Hubitat Elevation hub
Authored by: Support.com Tech Pro Team
1. Introduction
How to add and reset Everspring products on Hubitat Elevation hub
2. Resolution
Door/Window Detector
Product Number
Device Type
Protocol
HSM02
Contact Sensor
Z-Wave
Factory Reset
Press the tamper switch three times within 1.5 second. The LED will be steady on.
Within 1 second, press and hold the tamper switch until LED is off.
The LED will cycle on for 2 seconds and off for 2 seconds indicating the sensor has been reset for factory defaults.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Pressing the tamper switch three times within 1.5 second and the sensor will enter inclusion mode.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Pressing the tamper switch three times within 1.5 second will enter exclusion mode. The LED will light up once, each time the tamper switch is pressed.
Flood Detector
Product Number
Device Type
Protocol
ST812
Water Sensor
Z-Wave
Factory Reset
Press the link key three times within 1.5 second. The sensor will beep each time the link key is pressed.
Within 1 second, press and hold the link key. The sensor will long beep for 5 seconds. Keep holding the link key until the long beep stops.
The LED will cycle on for 2 seconds and off for 2 seconds indicating the sensor has been reset for factory defaults.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Pressing the link key three times within 1.5 second and the sensor will enter inclusion mode. The sensor will beep once, each time the link key is pressed.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Pressing the link key three times within 1.5 second will enter exclusion mode. The sensor will beep once, each time the link key is pressed.
Temperature/Humidity Detector
Product Number
Device Type
Protocol
ST814
Temperature Sensor
Z-Wave
Factory Reset
Pressing the temperature unit/linking key 3 times within 1.5 seconds will enter inclusion mode. The linking signal symbol will flash on the display.
Within 1 second, press the temperature unit/linking key again, and the sensor will emit a long beep. Keep holding the temperature unit/linking key until the long beep stops.
When the radio frequency status shows no signal, the device has been excluded from any previously joined Z-Wave networks and has been reset to factory defaults.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Pressing the temperature unit/linking key 3 times within 1.5 seconds will enter inclusion mode. The linking signal symbol will flash on the display.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Pressing the temperature unit/linking key 3 times within 1.5 seconds will enter inclusion mode. The linking signal symbol will flash on the display.
When the radio frequency status shows no signal, the device has been excluded from any previously joined Z-Wave networks
Illumination Sensor
Product Number
Device Type
Protocol
ST815
Light Sensor
Z-Wave
Factory Reset
Press the ESC button three times within 1.5 second.
Within 1 second, press and hold the ESC button.
The sensor will long beep. Keep holding the link key until the long beep stops.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Press the ESC button three times within 1.5 second and the sensor will enter inclusion mode. The sensor LED will flash.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the ESC button three times within 1.5 second and the sensor will enter exclusion mode. The sensor LED will flash.
PIR Detector
Product Number
Device Type
Protocol
HSP02
Motion Sensor
Z-Wave
Factory Reset
Press tamper switch three times within 1.5 second. The LED will be steady on.
Within 1 second, press and hold the tamper switch until LED is off.
The LED will cycle on for 2 seconds and off for 2 seconds indicating the sensor has been reset for factory defaults.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Pressing tamper switch three times within 1.5 second and the sensor will enter inclusion mode.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Pressing tamper switch three times within 1.5 second will enter exclusion mode.
Photoelectric Smoke Alarm
Product Number
Device Type
Protocol
SF813
Smoke Detector
Z-Wave
Factory Reset
Press tamper switch three times within 1.5 second. The LED flashes and the buzzer sounds when the link key is pressed.
Within 1 second, press and hold the tamper switch for 5 seconds until the LED is off.
The LED will light for 5 seconds and the buzzer will sound for 5 seconds
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Pressing tamper switch three times within 1.5 second and the sensor will enter inclusion mode. The LED flashes and the buzzer sounds when the link key is pressed.
The detector will stay awake and remain in inclusion mode for 10 minutes, or until the device has successfully joined the Z-Wave network.,
The LED will light for 1 second and the buzzer will sound for 1 second to indicated the detector has joined the Z-Wave network.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Pressing tamper switch three times within 1.5 second and the sensor will enter exclusion mode. The LED flashes and the buzzer sounds when the link key is pressed.
The detector will stay awake and remain in exclusion mode for 10 minutes, or until the device has successfully joined the Z-Wave network.,
The LED will light for 1 second and the buzzer will sound for 1 second to indicated the detector has been excluded from the Z-Wave network.