How to add and reset Heatit products on Hubitat Elevation hub
Authored by: Support.com Tech Pro Team
1. Introduction
How to add and reset Heatit products on Hubitat Elevation hub
2. Resolution
Thermostat
Device
Product Number
Device Type
Protocol
Z-Temp2
45 126 66
Thermostat
Z-Wave Plus
Factory Reset
Press and hold the link button for 20 seconds
rES will be displayed.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Press the link button 3 times quickly.
The thermostat will display INC when the thermostat is successfully included.
If inclusion fails, Err (error) will appear.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the link button 3 times quickly and wait for the exclusion process to finish. This will take a few moments to complete.
Device
Product Number
Device Type
Protocol
Z-TRM3
54 305 98
Thermostat
Z-Wave Plus
Factory Reset
Press both the Right and Center (down and confirm) buttons for 20 seconds.
The thermostat will be factory reset.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Press and hold the center button until OFF is shown on the display (approx. 10 seconds).
Press the down button 5 times until you reach CON
Press and hold until the display shows a rotating light pattern. The thermostat will display INC when the thermostat has successfully joined the Z-Wave network.
If inclusion fails, Err (error) will appear.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the down button 5 times until you reach CON
Press the center (confirm) for approximately 2 seconds and wait for the exclusion process to finish. This will take a few moments to complete.
Dimmer
Device
Product Number
Device Type
Protocol
Z-Dim
14 444 44
Dimmer
Z-Wave Plus
Factory Reset
By pressing and holding the main button for 20 seconds, the dimmer will be factory reset.
The connected light source will blink once and go in the OFF state if successfully reset.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Press the main button on the dimmer 6 times quickly.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the main button on the dimmer 6 times quickly. and wait for the exclusion process to finish. This will take a few moments to complete.
Repeater
Device
Product Number
Device Type
Protocol
Z-Repeater
45 126 86
Repeater
Z-Wave Plus
Factory Reset
When the device is excluded from the Z-Wave network, it will revert to factory settings.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Plug-in the device and within 1.5 seconds, press the function button 3 times.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Exclusion from the Z-Wave Network
Unplug the device.
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Plug-in the device and within 1.5 seconds, press the function button 3 times.
Wait for the exclusion process to finish. This will take a few moments to complete.
Smoke Detector
Device
Product Number
Device Type
Protocol
Z-Smoke 230V
45 126 89
Smoke Detector
Z-Wave Plus
Factory Reset
Excluding the device from the Z-Wave network will reset it to factory settings.
Join the Z-Wave Network
When power is applied, the smoke detector initiates a 1 minute warm-up period and will automatically enter inclusion mode.
After the calibration process is finished, access inclusion mode by pressing the function button 3 times within 1.5 seconds.
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the function button 3 times within 1.5 seconds and wait for the exclusion process to finish. This will take a few moments to complete.