How to add and reset Lutron products on Hubitat Elevation hub

Authored by: Support.com Tech Pro Team

1. Introduction

 

How to add and reset Lutron products on Hubitat Elevation hub

 

2. Resolution

Dimmer 

Product Number

Device Type

Protocol

Aurora

Button Controller

Zigbee

Factory Reset

  1. Quickly press the center button 3 times and hold on the thrid press for aproximatley 6 seconds until the LED flashes.
  2. Once LED is flashing quickly tap button 3 time again.
  3. The LED will flash rapidly to indicate the device has been successfuly reset for factory defaults.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery..
  2. Quickly press the center button on the Aurora 2 times to begin pairing.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove

Lutron Dimmers and Switches 

Product Number

Device Type

Protocol

 NIL

Dimmer / Switch

Lutron Clear Connect

Factory Reset

  1. Tap the "On" button quickly 3 times, holding on the last press.
  2. Continue to hold the "On" button until the light begins to flash quickly.
  3. Release the button, then immediately tap the button 3 more times.
  4. All paired Pico remote controls are removed and all settings are returned to factory default.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Caséta Smart Bridge Pro 

Product Number

Device Type

Protocol

L-BDGPRO2

Bridge

Lutron Clear Connect

Network Reset

  1. First, press and hold the black button on the back of your Smart Bridge for 20 seconds.

Factory Reset

  1. Quickly tap the button 3 times and hold. DO NOT release after the third tap.
  2. Continue to hold the Add button for a few seconds. The LEDs will begin to flash slowly (approximately once per second).
  3. Release the button and quickly tap the button 3 times. The LEDs will flash quickly and then will turn off. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly)
  4. The Lutron Smart Bridge Pro has now been returned to Factory Default Settings.
  5. Lutron does not recommend factory resetting a Smart Bridge Pro unless advised by a member of the Lutron technical support team. 

Pico Remote 

Product Number

Device Type

Protocol

PJ2-

Button Controller

Lutron Clear Connect

Factory Reset

  1. Tap the "On" button quickly 3 times, holding on the last press.
  2. Continue to hold the "On" button until the light begins to flash quickly.
  3. Release the button, then immediately tap the button 3 more times.
  4. All paired Pico remote controls are removed and all settings are returned to factory default.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Radio RA2 Keypads 

Product Number

Device Type

Protocol

 NIL

Keypad

Lutron Clear Connect

Factory Reset

  1. Tap the "On" button quickly 3 times, holding on the last press.
  2. Continue to hold the "On" button until the light begins to flash quickly.
  3. Release the button, then immediately tap the button 3 more times.
  4. The RA2 keypad has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Radio RA2 Main Repeater  

Product Number

Device Type

Protocol

RR-MAIN-REP

Repeater

Lutron Clear Connect

Factory Reset

  1. Tap the Test button on a Main Repeater 3 times. DO NOT release the button after the third tap.
  2. Keep the Test button pressed on the third tap until all the LEDs start to flash red slowly (approximately 3 seconds).
  3. Release the Test button and immediately tap 3 times again. All the LEDs will flash Red quickly.
  4. When the LEDs stop flashing, the Main Repeater has been returned to factory settings

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Radio RA2 Occupancy Sensors  

Product Number

Device Type

Protocol

 NIL

Motion Sensor

Lutron Clear Connect

Factory Reset

  • Radio Powr Savrâ„¢ Occupancy/Vacancy Ceiling Sensor – 1st Generation (LRF2-xCRB-)
  1. Quickly tap 3 times and hold the Test, Lights ON, or Lights OFF button on the Sensor. DO NOT release after third tap.
  2. Keep the button pressed after the third tap for a few seconds until the dome LED begins to flash slowly (approximately once per second).
  3. Release the button and tap it again 3 times until the dome LED on the Sensor flashes quickly. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The Sensor has now been returned to Factory Default Settings.
  • Radio Powr Savrâ„¢ Occupancy/Vacancy Ceiling Sensor – 2nd Generation (LRF2- xCR2B-)
  1. Quickly tap 3 times and hold the Test or Light button on the Sensor. DO NOT release after third tap.
  2. Keep the button pressed after the third tap for a few seconds until the dome LED begins to flash slowly (approximately once per second).
  3. Release the button and tap 3 times again until the dome LED on the Sensor flashes quickly. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The Sensor has now been returned to Factory Default Settings.
  • Radio Powr Savrâ„¢ Occupancy/Vacancy Wall-Mounted Sensor
  1. Quickly triple tap and hold the Sensor, Lights ON, or Lights OFF button on the Sensor. DO NOT release after third tap.
  2. Keep the button pressed after the third tap for a few seconds until the lens LED begins to flash slowly (approximately once per second).
  3. Release the button and tap it again 3 times until the lens LED on the Sensor flashes quickly. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The Sensor has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Radio RA2 Select Main Repeater  

Product Number

Device Type

Protocol

RR-SEL-REP2

Repeater

Lutron Clear Connect

Factory Reset

  1. Quickly tap 3 times and hold down any button on the Main Repeater. DO NOT release after the third tap.
  2. Continue to hold the button for a few seconds. The Main Repeater LEDs will begin to flash Red slowly (approximately once per second).
  3. Release the button and quickly tap 3 times again. The Main Repeater LEDs will flash Green rapidly and then will reset, turning off all LEDs and then flashing the LEDs and beeping once. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The Main Repeater and system components have now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device.

RadioRA2 VCRX Visor Control Receiver 

Product Number

Device Type

Protocol

RR-VCRX

Garage Controller

Lutron Clear Connect

Factory Reset

  1. Quickly tap 3 times and hold any button (except Learn) on the VCRX. DO NOT release after third tap.
  2. Keep the button pressed after the third tap for a few seconds until all the status LEDs start to flash slowly (approximately once per second).
  3. Release the button and tap 3 times again until all the status LEDs on the VCRX flash quickly. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The VCRX has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device.

Serena Shades  

Product Number

Device Type

Protocol

 NIL

Shade Control

Lutron Clear Connect

Factory Reset

  1. Tap the shade button quickly 3 times, and hold the shade button after the third tap until the shade button LED flashs Green rapidly.
  2. Immediately tap the shade button quickly 3 more times, until the shade button LED flashes Green rapidly, then flashes Red/Green 3 times, and turns off.
  3. The Serena shade has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Sivoia QS Triathlon Shades  

Product Number

Device Type

Protocol

 NIL

Shade Control

Lutron Clear Connect

Factory Reset

  1. Tap the shade button quickly 3 times, and hold the shade button after the third tap until the shade button LED flashs Green rapidly.
  2. Immediately tap the shade button quickly 3 more times, until the shade button LED flashes Green rapidly, then flashs Red/Green 3 times, and turns off.
  3. The Sivoia shade has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

RadioRA2 Fan Control  

Product Number

Device Type

Protocol

RRD-2ANF

Fan Controller

Lutron Clear Connect

Factory Reset

  1. Tap the tapswitch 3 times on a control. DO NOT release after the third tap.
  2. Keep the tapswitch pressed on the third tap (for approximately 3 seconds) until the LEDs on the dimmer start to scroll up and down quickly, or the LED on the switch flashes quickly
  3. Release the tapswitch and immediately tap it 3 times again.
  4. The LEDs on the dimmer will scroll up and down slowly and then the LED on the switch will flash slowly, indicating it has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device.

Lutron Caséta Fan Control  

Product Number

Device Type

Protocol

PD-FSQN

Fan Controller

Lutron Clear Connect

Factory Reset

  1. Tap the "On" button quickly 3 times, holding on the last press.
  2. Continue to hold the "On" button until the light begins to flash quickly.
  3. Release the button, then immediately tap the button 3 more times.
  4. All paired Pico remote controls are removed and all settings are returned to factory default.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device