4 Channel Dimming Controller  

Product Number

Device Type

Protocol

ZB-1003

Dimmer

Zigbee

Factory Reset

  1. Press the program button quickly 5 times, or if the unit is not accessible, power the device off and on quickly 5 times.
  2. The LED will flash quickly and then stay in a slow rhythmic breathing pattern to indicate a successful reset.

Join the Zigbee Network

  1. Press the program button quickly 5 times, or if the unit is not accessible, power the device off and on quickly 5 times.
  2. The LED will flash quickly and then stay in a slow rhythmic breathing pattern to indicate a successful reset and the device is ready for pairing.
  3. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Factory reset the device.

RGBW Color controller  

Product Number

Device Type

Protocol

ZB-1025

Dimmer

Zigbee

Factory Reset

  1. Press the program button quickly 5 times, or if the unit is not accessible, power the device off and on quickly 5 times.
  2. The LED will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.

Join the Zigbee Network

  1. Press the program button quickly 5 times, or if the unit is not accessible, power the device off and on quickly 5 times.
  2. The LED will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.
  3. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Factory reset the device.

Product Number

Device Type

Protocol

ZW-1001

Dimmer

Z-Wave Plus

Factory Reset

  1. Press and hold down the Inclusion/Exclusion button for over 10 seconds
  2. The connected LED light will stay ON solid for 3 seconds to indicate a successful factory reset
  3. Release the Inclusion/Exclusion button and all 4 PWM outputs will restore to 50% brightness.

Join the Z-Wave Network

  1. Power on the LED dimmer
  2. If the connected LED light has a solid ON status, it means the LED dimmer has already been included in a network, and first, you have to set the LED dimmer into Exclusion mode.
  3. Once excluded, it will be set into Inclusion mode automatically, and waiting to be included in the Z-Wave network.
  4. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Triple press the “inclusion/exclusion” button
  4. The LED dimmer will be set to Exclusion mode and the connected LED light will flash quickly for 6 seconds
  5. The LED light will stay ON solid for 3 seconds to indicate successful exclusion.

Product Number

Device Type

Protocol

ZW-1002

Dimmer

Z-Wave Plus

Factory Reset

  1. Press and hold down the Inclusion/Exclusion button for over 10 seconds
  2. The connected LED light will stay ON solid for 3 seconds to indicate a successful factory reset
  3. Release the Inclusion/Exclusion button and all 4 PWM outputs will restore to 50% brightness.

Join the Z-Wave Network

  1. Power on the LED dimmer
  2. If the connected LED light has a solid ON status, it means the LED dimmer has already been included in a network, and first, you have to set the LED dimmer into Exclusion mode.
  3. Once excluded, it will be set into Inclusion mode automatically, and waiting to be included in the Z-Wave network.
  4. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Triple press the “inclusion/exclusion” button
  4. The LED dimmer will be set to Exclusion mode and the connected LED light will flash quickly for 6 seconds
  5. The LED light will stay ON solid for 3 seconds to indicate successful exclusion.

Single color remote  

Product Number

Device Type

Protocol

ZW-5121

Button Controller

Zigbee

Factory Reset

  1. Press and hold the middle (Light ON) button.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the middle (Light ON) button.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the middle (Light ON) button.

RGB color remote  

Product Number

Device Type

Protocol

ZW-5122

Button Controller

Zigbee

Factory Reset

  1. Press and hold the middle (Light ON) button.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the middle (Light ON) button.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the middle (Light ON) button.

Monochrome controller panel  

Product Number

Device Type

Protocol

ZB-3026

Button Controller

Zigbee

Factory Reset

  1. Press and hold down the power button on the Touch Panel until the LED indicator turns on.
  2. Immediately press the power button 5 times.
  3. The LED indicator will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the power button until the LED status indicator turns on.
  3. Immediately press the S1 button once to enable the Touch Panel to search for nearby networks. The LED indicator will flash once every second.

Verifying network pairing

  1. Quickly press any button and the LED indicator should flash once.
  2. If the LED indicator does not respond, the Touch Panel is not paired with a network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Single Channel Trailing Edge Dimmer 

Product Number

Device Type

Protocol

ZB-4002

Dimmer

Zigbee

Factory Reset

  1. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Single Channel Microcontroller and Lamp Module 

Product Number

Device Type

Protocol

ZB-4003

Switch

Zigbee

Factory Reset

  1. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

3 Zone Color Touch Panel 

Product Number

Device Type

Protocol

ZB-5027

Button Controller

Zigbee

Factory Reset

  1. Press and hold down the power button on the Touch Panel until the LED indicator turns on.
  2. Immediately press the power button 5 times.
  3. The LED indicator will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the power button until the LED status indicator turns on.
  3. Immediately press the S1 button once to enable the Touch Panel to search for nearby networks. The LED indicator will flash once every second.

Verifying network pairing

  1. Quickly press any button and the LED indicator should flash once.
  2. If the LED indicator does not respond, the Touch Panel is not paired with a network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Color Remote 

Product Number

Device Type

Protocol

ZB-5028

Button Controller

Zigbee

Factory Reset

  1. Press and hold down the power button on the Touch Panel until the LED indicator turns on.
  2. Immediately press the power button 5 times.
  3. The LED indicator will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the power button until the LED status indicator turns on.
  3. Immediately press the S1 button once to enable the Touch Panel to search for nearby networks. The LED indicator will flash once every second.

Verifying network pairing

  1. Quickly press any button and the LED indicator should flash once.
  2. If the LED indicator does not respond, the Touch Panel is not paired with a network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Microcontroller and Lamp Module  

Product Number

Device Type

Protocol

ZW-4001

Dimmer

Z-Wave Plus

Factory Reset

  1. Press and hold down the Reset button for over 10 seconds

Join the Z-Wave Network

  1. Power on the microcontroller
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the Reset button 3 times quickly.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Reset button 3 times quickly.