How to add and reset Zooz products on Hubitat Elevation hub

Authored by: Support.com Tech Pro Team

1. Introduction

How to add and reset Zooz products on Hubitat Elevation hub

 

2. Resolution

Smart Plug

Device

Product Number

Device Type

Protocol

Smart Plug

ZEN06

Outlet

Z-Wave Plus

Factory Reset

  1. Plug the smart plug into a grounded receptacle.
  2. PRESS AND HOLD the Z-Wave button for at least 20 seconds.
  3. The LED indicator will stay solid yellow for 2 seconds to indicate successful reset and the plug will then automatically turn off.

Join the Z-Wave Network

  1. Plug the smart plug into a grounded receptacle located within 3 feet from your Z-Wave radio.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press and release the Z-Wave button 3 times quickly.
  4. The LED indicator will flash blue.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the Z-Wave button 3 times quickly to exclude it from the Z-Wave network.
  3. LED indicator will flash orange.
  4. The LED indicator will remain solid orange for a few seconds to indicate successful exclusion from the Z-Wave network.

Power Switch

Device

Product Number

Device Type

Protocol

Power Switch

ZEN15

Switch

Z-Wave Plus

Factory Reset

  1. Plug the power switch into a grounded receptacle.
  2. PRESS AND HOLD the Z-Wave button for at least 20 seconds.
  3. The LED indicator will flash orange and then stay solid orange for 2 seconds to indicate successful reset and the switch will then automatically turn off.

Join the Z-Wave Network

  1. Plug the smart plug into a grounded receptacle located within 3 feet from your Z-Wave radio.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press and release the Z-Wave button 3 times quickly.
  4. The LED indicator will start flashing blue, then turn blue (on) or pink (off) once included to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the Z-Wave button 3 times quickly to exclude it from the Z-Wave network.
  3. LED indicator will flash orange.
  4. The LED indicator will start flashing blue, then turn blue (on) or pink (off) once excluded from the Z-Wave network.

MultiRelay

Device

Product Number

Device Type

Protocol

MultiRelay

ZEN16

Switch

Z-Wave Plus

Factory Reset

  1. Press the Z-Wave button 4 times quickly.
  2. The LED indicator will light up, then quickly press the Z-Wave button 4 times again.
  3. If theLED indicator flashes 3 times then turns oft, reset was successful.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave button 5 times quickly to add the MultiRelay to your network.
  3. The LED indicator will flash to signal communication and remain on for 2 seconds to confirm inclusion.

Exclusion from the Z-Wave Network

  1. Bring your MultiRelay close to the hub and ensure is has power.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave button 3 times quickly.
  4. Hubitat Elevationâ„¢ will confirm exclusion and the MultiRelay will disappear from the device list.

Power Strip Ver 2.0

Device

Product Number

Device Type

Protocol

Power Strip Ver 2.0

ZEN20

Power Strip

Z-Wave Plus

Factory Reset

  1. Plug the Power Strip into a grounded receptacle.
  2. Tap the CH1 button 3 times and hold on the third tap for at least 10 seconds.
  3. All LED indicators will flash to confirm successful reset.

Join the Z-Wave Network

  1. Plug the Power Strip into a grounded receptacle you’re planning to use it at (it doesn’t need to be close to the hub).
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press and release the CH1 button 3 times quickly.
  4. All LED indicators will start flashing.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the CH1 button 3 times quickly.

Smart Switch

Device

Product Number

Device Type

Protocol

Smart Switch

ZEN21

Switch

Z-Wave Plus

Factory Reset

  1. Tap the upper paddle 3 times and hold on the third tap for at least 10 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the top paddle 3 times quickly.
  3. The LED indicator will flash to signal communication.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Tap the bottom paddle 3 times quickly to exclude it from the Z-Wave network.

Dimmer Switch

Device

Product Number

Device Type

Protocol

Dimmer Switch

ZEN22

Dimmer

Z-Wave Plus

Factory Reset

  1. Tap the upper paddle 3 times and hold on the third tap for at least 10 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the top paddle 3 times quickly.
  3. The LED indicator will flash to signal communication.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Tap the bottom paddle 3 times quickly to exclude it from the Z-Wave network.

ON/OFF Toggle Switch

Device

Product Number

Device Type

Protocol

ON/OFF Toggle Switch

ZEN23

Switch

Z-Wave Plus

Factory Reset

  1. Toggle the switch down 3 times and hold on the third toggle for at least 10 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Toggle the switch up 3 times quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Toggle the switch down 3 times quickly to exclude it from the Z-Wave network.

Dimmer Toggle Switch

Device

Product Number

Device Type

Protocol

Dimmer Toggle Switch

ZEN24

Dimmer

Z-Wave Plus

Factory Reset

  1. Toggle the switch down 3 times and hold on the third toggle for at least 10 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Toggle the switch up 3 times quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Toggle the switch down 3 times quickly to exclude it from the Z-Wave network.

S2 ON/OFF Switch

Device

Product Number

Device Type

Protocol

S2 ON/OFF Switch

ZEN26

Switch

Z-Wave Plus

Factory Reset

  1. Tap the upper paddle 3 times and hold on the third tap for at least 10 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the top paddle 3 times quickly.
  3. The LED indicator will flash and will remain ON for 2 seconds to indicate successful communication.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Tap the bottom paddle 3 times quickly to exclude it from the Z-Wave network.

S2 Dimmer Switch

Device

Product Number

Device Type

Protocol

S2 Dimmer Switch

ZEN27

Dimmer

Z-Wave Plus

Factory Reset

  1. Tap the upper paddle 3 times and hold on the third tap for at least 10 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the top paddle 3 times quickly.
  3. The LED indicator will flash and will remain ON for 2 seconds to indicate successful communication.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Tap the bottom paddle 3 times quickly to exclude it from the Z-Wave network.

Double Switch

Device

Product Number

Device Type

Protocol

Double Switch

ZEN30

Switch

Z-Wave Plus

Factory Reset

  1. Press and hold the lower paddle on the dimmer for at least 15 seconds until the LED indicators start flashing, then release.
  2. Immediately press and hold the upper paddle on the dimmer for at least 15 seconds.
  3. The LED indicators will flash again to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the upper paddle 3 times quickly to include the device in the Z-Wave network.
  3. The LED will flash to indicate communication with the hub and will stay on for 2 seconds indicate it has been successfully added to your network.

Exclusion from the Z-Wave Network

  1. Bring your Hubitat Elevationâ„¢ hub close to the RGBW Dimmer if possible.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the lower paddle 3 times quickly to exclude it from the Z-Wave network.

RGBW Dimmer

Device

Product Number

Device Type

Protocol

RGBW Dimmer

ZEN31

Dimmer

Z-Wave Plus

Factory Reset

  1. Press and hold the Z-Wave button to enter reset mode.
  2. Release the button when the LED indicator glows Yellow, then quickly press the Z-Wave button again to confirm factory reset.
  3. Wait a few seconds until the device resets and restarts.
  4. The LED indicator will light up in Red when it’s ready.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave button 3 times quickly to include the device in the Z-Wave network.
  3. The LED will flash Yellow to indicate communication with the hub.
  4. The LED will flash Green to indicate it has been successfully added to your network.
  5. If inclusion fails, the LED will flash Red.

Exclusion from the Z-Wave Network

  1. Bring your Hubitat Elevationâ„¢ hub close to the RGBW Dimmer if possible.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave button on the device 3 times quickly.
  4. The LED indicator on the RGBW Dimmer will light up in Red, and the device will disappear from the devices list.

Motion Sensor

Device

Product Number

Device Type

Protocol

Motion Sensor

ZSE02

Motion Sensor

Z-Wave Plus

Factory Reset

  1. Please press the Z-Wave button 6 TIMES quickly (3 unlock-lock cycles).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Bring the motion sensor within direct reach of your Z-Wave radio.
  3. Quickly press the Z-Wave button on the motion sensor 2 times (unlock and then lock).
  4. Make sure the button is pushed in (locked) when you finish the process to re-enable motion detection.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press the Z-Wave button on the motion sensor 2 times (unlock and then lock).

Motion and Light Mini Sensor

Device

Product Number

Device Type

Protocol

Motion and Light Mini Sensor

ZSE09

Motion Sensor

Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the Z-Wave button for at least 10 seconds.
  2. The LED indicator flashes 1 time and it may then flash 5 times to indicate the device is no longer part of Z-Wave network.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Mini Sensor 3 times.
  3. The LED indicator will flash quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Mini Sensor 3 times.
  3. The LED indicator will flash quickly.

Motion Sensor

Device

Product Number

Device Type

Protocol

Motion Sensor

ZSE18

Motion Sensor

Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the Z-Wave button for at least 20 seconds.
  2. The LED indicator will turn on then turn on solid and will then automatically turn off.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the 4-5 times.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the 3 times.

Multisiren

Device

Product Number

Device Type

Protocol

Multisiren

ZSE19

Siren

Z-Wave Plus

Factory Reset

  1. Press the Z-Wave button 4 times and hold on the fourth press for at least 5 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button 4-5 times.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button 3 times.

S2 Outdoor Motion Sensor

Device

Product Number

Device Type

Protocol

S2 Outdoor Motion Sensor

ZSE29

Motion Sensor

Z-Wave Plus

Factory Reset

  1. Press the tamper switch 4 times and hold on the fourth press for at least 5 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the tamper switch 4-5 times.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the tamper switch 3 times.

Water Sensor

Device

Product Number

Device Type

Protocol

Water Sensor

ZSE30

Water Sensor

Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the Z-Wave button for at least 10 seconds until the LED indicator flashes 1 time.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Water Sensor 3 times.
  3. The LED indicator will flash quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Water Sensor 3 times.
  3. The LED indicator will flash quickly.

Smart Chime

Device

Product Number

Device Type

Protocol

Smart Chime

ZSE33

Doorbell

Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the Z-Wave button for at least 10 seconds until the LED indicator flashes 1 time.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Water Sensor 3 times.
  3. The LED indicator will flash quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Water Sensor 3 times.
  3. The LED indicator will flash quickly.

4 in 1 Sensor

Device

Product Number

Device Type

Protocol

4 in 1 Sensor

ZSE40

Motion Sensor

Z-Wave Plus

Factory Reset

  1. OPEN the back cover to trigger tamper switch.
  2. Press and release the Z-Wave button using a paperclip 10 times quickly (within 10 seconds).
  3. The sensor will start flashing immediately and will again flash 5 times after the 10 clicks (color depends on room temperature, it’s usually blue or yellow).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button 2 times with a paperclip.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button 2 times with a paperclip.

Water Valve

Device

Product Number

Device Type

Protocol

Water Valve

ZAC03

Valve

Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the RED power button for at least 10 seconds until the LED indicator flashes 1 time.

Join the Z-Wave Network

  1. Connect the valve to power.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Quickly press the RED power button on the valve control 3 times.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press the RED power button on the valve control 3 times.